Blog

COAL TAR EPOXY AMINE HB 844 T HB

  |   EPOXY POLY AMINE   |   No comment
رنگ ضد حریق

EN.TDS

Product information

1-Ballast tank coating with outstanding water resistance.

2-Excellent corrosion resistance.

3-Good resistance against chemically polluted water.

4-For tank coating,immersion or non-immersion service.

5-Excellent adhesion to steel and concrete.

 

 

Physical data    

Colour:                                                       green , black , brown

Finish:                                                        Flat

Flash point:

           Resin:                                            38°c

           Cure:                                             24°c

           Solvent:                                         28°c

Volume solids:                                          94±2%

D.f.t:                                                            100 – 150  microns

Specific gravity(mixed):                          1.56  ±  0.05gr/cm3 

Theoretical coverage:                             6.6 m2 /lit (at 100 µ d.f.t)

Drying time at 25°c:

                Touch dry:                               6hrs

        Dry to handle:                                 24 hrs

                 Full cure:                                7 days

Component:                                             2

Pot life:                                                      4 hrs at 25°c:

Mixing ratio(by volume):

                                    Resin:                refer to can label

                                    Cure:                  refer to can label

Application methods:                              conventional spray or

                                                             Airless spray or roller

Recoat intervals*:                                  10°c                 25°c             40°c

(mild condition) :  Min:                           25  hrs           12 hrs           5  hrs

                       **Max:                           NONE             NONE         NONE

**Maximum Recoat: Unlimited. Must have a clean, dry surface for top coating.”Loose” chalk or salts must be removed in              .        accordance with good painting practice. Drying time is temperature, humidity, and fi lm thickness dependent

ZINC PHOSPHATE EPOXY AMINE PRIMER RANA 847 P
مطالعه

Recommended thinner:                       RANA THINN 84

Recommended cleaner:                        RANA CLEAN 84

Shelf life:                                                   12 months when stored indoors in unopened

Original containers at 5 to 40°c (cool and dry

                        Place).

Curing mechanism:                                by solvent release and reaction by curing

                                                                    Agent and resin

Substrate:                                               steel, primed steel, concrete

* : For recoating the surface should be free of dust ,grease  and contamination

 
Typical uses

This RANA CHEM’s product is recommended for long time

corrosion protection of structural steel and concrete

in severe corrosive and immersed environments.

Typical areas are steel buried in aggressive soil,pipelines

of steel and concrete,tanks containing fuel or lubrication

oil,drill water,drill mud,warm water or steel and concrete

in sewage treatment plants.

Application information

This product is a polyamine cured ,coaltar epoxy high build

coating for non-immersion as well as immersion service

excellent corrosion and chemical resistance

and full film thickness in only one coat.

EPOXY AMINE INTERMEDIATE COAT 843 I
مطالعه

To obtain the maximum performance for which this product

is formulated strict adherence to all application instructions,

precautions,conditions and limitations is necessary.

 
Application equipment

The following equipment is listed as a guide and suitable

equipment from other manufactures may be used .

Adjustments of pressure and change of tip size may be

needed to obtain the proper spray characteristics:

1-Airless spray: Standard airless spray equipment having

a 28:1 or higher pump ratio and a fluid tip with a 0.457 to 0.914 mm

orifice.

2-Conventional spray:industrial equipment with suitable

   aircap having a fluid tip with a 1.8-2 mm orifice.

3-Mixer: use power mixer powered by an air motor or an

    explosion proof electric motor.

.

   FARCO TOP 110HB

Caution

1-Handle with care.

2-Before and during use ,observe all safety labels on

Packaging and paint containers.

3-Harmful or fatal if swallowed, immediately seek medical

assistance.

4-Always take precautions against the fire and explosions.

5-Use with adequate ventilation.

6-Don’t empty into drains.

7-Take precautionary measures against static discharge.

COAL TAR EPOXY AMINE RANA 844 T
مطالعه

    Application procedures    

1-Flush  equipment with cleaner before use.

2-Stir resin to an even consistency with a power mixer.

3-Add cure to resin and continue stirring for 5 minutes.

Note: since the pot life is limited and shortened by high

temperatures ,do not mix more material than will be used

in 4 hours at 25°c.

4- Thinning  with RANA THINN 84 as needed for workability .

5-Stir during application to maintain uniformity of material

And apply a wet coat in even parallel passes after 20 minutes.

6-Clean all equipment with cleaner immediately after use .

Environmental condition

       Environmental temperature must be 10-40°c.

Surface temperature must be at least 3°c above dew point

       to prevent condensation. At freezing temperature surface

       must be free of ice and relative humidity below 80 %.

Surface preparation

The surface must be clean and dry . All dirt , grease ,

mill scale and any other foreign material should be

removed.sand blasting to a standard of Sa 2.5 – Sa3 , SIS 05 5900 , ISO 8501-1.

No Comments